Document Information
- Document Tracking Number
-
dof-2010-2
- Document Version
-
7.0.1, 12 January 2018
- Build Version
-
7.0.1.8
- Source Information
-
2018-01-12, "." at commit c4a21c8bf741a32d4fe20776861d03baab74639a on branch "master" of repository core-specifications
- External Reference
-
DOF Object Model Types, OpenDOF TSC, [dof-2010-2] (7.0.1, 12 January 2018)
This document is managed by the Technical Steering Committee of the OpenDOF Project, Inc.. Contact the committee using the following information.
Contact Information
- Post Mail
-
OpenDOF Project, Inc.
Technical Steering Committee
3855 SW 153rd Drive
Beaverton, OR 97003 - Telephone
-
1-503-619-4114
- Fax
-
1-503-644-6708
Copyright
Copyright © 2008-2018 Panasonic Corporation, Bryant Eastham
Patents
Contributors to the OpenDOF Project make a non-enforcement pledge related to any patent required to implement the protocols described in this document. For more information see https://opendof.org/pledge.
License
1. About This Document
This document contains reference information for DOF Object Model Type formats. DOF data types are extensible, with its base defined in the DOF Common Types specification.
Each Type and data format is defined by a Type Identifier, which is registered with the Technical Steering Committee of the OpenDOF Project, Inc. (ODP-TSC) before use. This document contains many of these defined formats, but not all of them. The registry of Type Identifier assignments (found at https://opendof.org/registry-types) contain links to other defining documents.
1.1. Audience
The primary audience of this document is people implementing libraries that use DOF protocols. Others that are concerned about how DOF protocols work on a network at a very low level can also benefit from this document.
Readers should be familiar with technical protocol documentation. This document is similar to an 'RFC' for DOF protocols, and familiarity with the language used in these types of documents is helpful.
This document is not required reading for those who need to use existing DOF libraries, although system designers may benefit from an understanding of this information. In particular, the information related to security and connections can help system designers to better understand how DOF systems work.
1.2. Authority
This document, in its English form, is the authoritative document for DOF protocols. Due to the detailed nature of protocol design, it may be difficult for a reader to implement these protocols correctly based on a translated document. When questions arise, the English version is authoritative.
All implementations that claim to be DOF compliant must satisfy the requirements set forth in this document.
This document is managed by the Technical Steering Committee of the OpenDOF Project, Inc., referred to as 'ODP-TSC'. The inside cover of this document contains contact information for the Technical Steering Committee.
The web site for the Technical Steering Committee is https://opendof.org/tsc.
1.3. PDU Definitions
This document deals with the transmission of information on a network. In order to describe this, diagrams show different fields, their network order, and positioning.
All DOF protocol documentation uses a similar diagramming style, discussed in this section. The word 'PDU', which stands for 'Protocol Data Unit', indicates these diagrams.
1.3.1. Context
Each PDU represents information sent on the network in some context. This usually means that there is information sent 'surrounding' the PDU itself. This information provides the 'context' for the PDU.
For example, the context for the DOF Protocol Stack itself is a network transport. This could be UDP/IP, TCP/IP, or any other transport. The transport will require certain headers and trailers, but they are not shown in each DOF Protocol Stack PDU. In this example the transport provide the context of the DOF Protocol Stack PDU.
In a similar way, the DOF Protocol Stack defines the context for the other DOF protocols. The Object Access Protocol, for example, can use the DOF Protocol Stack for its context. Just as the transport headers are not shown for the DOF Protocol Stack, the DOF Protocol Stack headers are not shown for the Object Access Protocol.
Understanding the context requires understanding the relative position of the different layers in the protocol stack. Each PDU defines the ordering of all of its parts, and may indicate that it is itself an instance of some other general PDU format. This means that it is always possible to start at a high-level PDU definition and understand it completely, but not always possible to identify everywhere that a particular PDU may be used (as a part of some other higher-level PDU).
Each protocol specification defines its specific contexts. The context definition includes a description of the underlying stack layer (or the containing layer), and defines the information that must be available from that layer (for reception) or passed to that layer (for transmission).
As an example, the context of the DOF Network Protocol is a transport. The transport has a requirement to provide the addresses of nodes, and so part of the context for the transport is the sender address (for reception) or the target address (for transmission). Any transport that will work with the DOF Protocol Stack must meet the context requirements.
1.3.2. Generalization
Many times a particular PDU will be a specific type of a more general PDU. In these cases, the PDU will indicate that it is an 'instance' of the more general type.
1.3.3. Qualifications
Each PDU will have qualifications placed on its use. The general qualifications include security and transport requirements. The following terms identify these qualifications. Others may be present as well.
Transport Qualifications
There are three major transport categories for DOF protocols (see the DOF Protocol Specification, Transport Requirements). These are None, Lossy, and Lossless. There are also three addressing types: Unicast, Multicast, and Broadcast. PDUs indicate the ability to use each of these categories as follows:
Session: Combinations of None, Lossy (2-node, n-node), or Lossless. Addressing: Combinations of Unicast, Multicast, or Broadcast.
Security Qualifications
Each PDU categorizes security qualifications according to the major aspects of security (see the DOF Security Specification, Overview). These are Encryption, Data Integrity, Authentication, and Access Control. Encryption prevents viewing of the PDU, Data Integrity ensures that others do not modify the PDU, Authentication indicates knowledge of the nodes involved in the communication, and Access Control restricts those able to use the PDU.
Data Integrity is required according to the DOF Protocol Stack specification for all secure packets. Authentication is required whenever permissions are involved, or when it is important to know something about the relationship between the sender and receiver. Encryption is required if the contents of the packet contain information that must not be visible to potential attackers.
In addition, there is the case of unsecured communication. PDUs that do not require security will list 'Unsecured' as a possible choice. Finally, certain PDUs are required to be Unsecured, and are identified as such.
Each application PDU must specify its security requirements. If Access Control is required, the PDU will indicate the permissions required for the command and for any response. However, it is typical for all of the PDUs of a given protocol to share the same requirements, and so the protocol specification may define its security qualifications in a single section. In this case, the individual PDUs should refer back to this section to avoid confusion.
It is also typical for applications to require the security of the session. A PDU indicates this as 'session security', and is its own security qualification. If the PDU allows the 'None' session type then this implies that Unsecured is allowed, as session type 'None' cannot be secure.
For PDUs that refer to session security or a common security section, one of the following formats is used:
Security: See the section 'Security Qualifications'.
or
Security: Session.
The PDU uses the following identifications to specify the security qualifications for a PDU:
Unsecured: (description). Encryption: (description). Message authentication: (description). Permission (command): (description). Permission (response): (description).
For each of these, the (description) varies. There are many different combinations of values, as described here.
Unsecured can have the values 'Required', 'Allowed', 'Not Allowed'.
Encryption can have the values 'Required', 'Allowed', 'Not Allowed'.
Message authentication can have the values 'Required', 'Allowed', 'Not Allowed'.
The specific PDU determines the permissions required (for both command and response).
There are combinations that are not valid. The following table defines all allowed combinations if a combination does not appear in the table then it is invalid.
In general, security theory links Encryption and Data Integrity. If one is 'Required' then the other must at least be 'Allowed'. Encryption and Data Integrity are the opposite of Unsecured. If either is 'Required' then unsecured must be 'Not Allowed'. Again, note that since data integrity is a common requirement for all secure packets the PDUs do not list it separately.
| Unsecured / Encryption / Message Authentication | Description |
|---|---|
Required / Not Allowed / Not Allowed |
Indicates the PDU must be unsecured. |
Allowed / Allowed / Allowed |
Indicates there are no security requirements. |
Not Allowed / Allowed / Allowed |
Indicates the PDU must be either encrypted or authenticated. This is the lowest level of security possible for a PDU. |
Not Allowed / Required / Allowed |
Indicates that encryption is required, and data integrity is optional. |
Not Allowed / Allowed / Required |
Indicates that encrypted is optional, but authentication is required. |
Not Allowed / Required / Required |
Indicates both encryption and authentication are required. |
1.3.4. Fields
Each PDU shows a container, represented as a sequence of fields. The table fully describes each field.
The following is an example of a PDU description.
|
Example PDU |
The container represents the PDU. The diagram shows Fields first to last, left to right and top to bottom. This means that the first fields appear on the wire before the last fields. This is a general principle: things on the top and toward the left in the diagrams appear on the wire before things on the right and bottom. Note that the transport is free to use whatever ordering it must, and memory layout may different from the PDU definition. However, the transfer of a PDU from a program, over an arbitrary transport and into another program must maintain the perceived ordering between the two programs. PDU diagrams are always shown MSB first (most significant byte) and msb first (most significant bit) unless otherwise indicated.
Each field identifies its contents and provides information necessary to understand its use.
In the example above, the diagram shows the first six fields of the container.
Each field is named, with the exception of reserved fields which are indicated as being grayed out.
Field names use monospace text similar to that used in program listing.
The third field shown is indicated as reserved.
Reserved bits have special requirements described in the DOF Protocol Specification.
Several different field cases are typical, described in the following sections.
Typical Field
A typical field defines its name, its type, and its description.
As shown, this field is not optional, and so it must appear in the position indicated by the diagram.
The PDU uses Field Name throughout the related documentation to refer to the field.
The type of the field is a reference to some other defined PDU.
Otherwise, the PDU indicates the size of the field and any defined structure.
Optional Field
An optional field is similar to the typical case, but is indicated as optional in a note to the right. Each optional field will indicate what controls whether or not it is included as well as the default value that the field takes on when it is absent.
Fixed Values
Fields may have required values based on the specific PDU. This is common in the case of a PDU being an instance of another PDU, where the specific instance requires certain field values. In this case, it is not valid for the PDU to contain values other than that specified, if so the PDU is invalid.
The required value is shown to the right of the field as a comment.
Bit Fields
It is common for PDUs to leverage a single byte to store multiple fields (bit fields). The packing of multiple fields into a single byte is indicated as shown in the earlier example. This packing of bits may also leave space that can be indicated as reserved.
The PDU indicates reserved bits visually although the PDU does not individual name these fields.
Note that bit fields may specify default values just as other fields. However, single bit fields do not show their hexadecimal representation. In addition, bits without names that have required values may indicate their values in the place of the name.
1.4. Specifications, Notes and Warnings
This is a technical specification document. It is critical to understand how the document indicates specification items. There are also annotations for notes (implementation notes or other information that is worthy of extra notice) and warnings (pitfalls or extremely critical information). In addition, there are implementation notes, which point out optimizations that are not obvious.
Each type of callout ends either when another callout begins or when the text goes back to the normal indentation.
|
This is a note. The text is inset and there is a header to indicate the beginning of the text. |
|
This is an implementation note. The text is inset and there is a header to indicate the beginning of the text. |
|
This is a warning. The text is bold inset and there is a different header to indicate the beginning of the text. |
|
This is an example This is the text. |
Following the summary is descriptive information about the specification item. Each specification item has a unique number assigned.
1.5. Printing This Document
The format of this document is for two-sided printing on US Letter paper.
1.6. Comparing Documents
The easiest way to compare versions of this document is to compare the corresponding source. The source format is AsciiDoctor, which is a markup-style text format. This format can be compared using any text comparison tool, including those that work with source control documents. To facilitate determining the source for each document there is information about the commit, branch, and repository along with the document version information. In addition the following guidelines are followed to make things easy to compare:
-
The input files put each sentence on a separate line, with no hard line-wrapping.
-
To the extent possible, macros and templates are used to determine formatting and structure.
-
Graphics and diagrams also use text formats.
If all you have available is a compiled document (PDF or HTML) then there are tools available to compare them. This section summarizes some of these methods with their pros and cons.
1.6.1. Text Comparison
There are several free tools that will do comparisons of the text of a PDF. One of these is the xdocdiff plugin for WinMerge. The plugin extracts the text from the PDF (including some information like page numbers), and WinMerge then compares the text.
WinMerge is available from http://winmerge.org. The xdocdiff plugin is available from http://freemind.s57.xrea.com/xdocdiffPlugin/en/index.html.
1.6.2. Graphical Comparison
In order to compare formatting, or to see the changes in the context of the document, a graphical compare is required. There are several free tools, but each has limitations.
-
diff-pdf, available from https://github.com/vslavik/diff-pdf, shows an overlay of the matching pages in different colors.
-
DiffPDF, available fromhttp://www.qtrac.eu/diffpdf.html, shows side-by-side red-lined differences of matching pages.
Both of these tools suffer from their page-by-page comparison methods. This means that when context shifts because of additions or removals that they start sensing changes at each page boundary. DiffPDF has the ability to select comparison ranges, allowing the program to synchronize at the beginning of each section, but this requires manual configuration and can be difficult for large documents.
There are also commercial tools that do an excellent job at comparing PDF documents. The first is Adobe Acrobat (http://www.adobe.com/products/acrobat.html), which in later releases has a 'Compare Document' feature. The result of the comparison is an annotated PDF, and hovering the mouse over the change will show the details.
Another commercial tool is PDF Content Comparer (http://www.inetsoftware.de/products/pdf-content-comparer) from i-net Software. This tool does side-by-side comparison, but has an intuitive auto-synchronize that keeps similar content lined up even when additions or deletions have occurred.
2. Introduction
Each Type Identifier is required to define its format and the format of the values it defines. The type format extends a standard PDU defined in DOF Common Types.
This document contains many of these additional type and value definitions. Each section presents a type, the structure of its data, and the structure of the data values that it defines.
All use of these formats must adhere to the requirements specified for the type. Failure to meet the requirements is a serious error that can affect interoperability of DOF systems.
|
The types described in this document are independent of protocol versioning. They are common among all DOF protocol versions, and are fixed. They can be added to over time, and protocols that use those new types can be negotiated if necessary according to the DOF Protocol Stack specification. |
Throughout this document are references to "ODP-TSC" which is the Technical Steering Committee of the OpenDOF Project, Inc. Contact information for the ODP-TSC is at the beginning of this document (inside cover page).
3. Type and Value Formats
The following sections describe the specifications for many types supported by DOF implementations. Note that it is not possible for a receiver to extract data for types that it does not understand. This is acceptable in most cases, because the implementer would program the receiver to understand a particular interface definition including the types that the interface requires. There are exceptions to this, typically for general user applications that can discover and interact with many interfaces including those it has not previously seen. In this case, the applications should be updated whenever new types are added, or it cannot know how to use those types.
3.1. Integer Types
DOF supports signed and unsigned integers with lengths from 1 byte up to 8 bytes.
The rules for different sizes of integer types are all very similar. This document combines them, with only a mention of the differences. In addition, the section combines the specifications for unsigned vs. signed types here with only a note of the differences.
The main difference is the value format on the wire. In each case, the value on the wire contains the same number of bits as the type declares. The values are MSB first. The signed types are 2’s complement.
|
3.1.1. Unsigned 8-bit Integer
The value is one byte using Integer Wire Format.
|
Unsigned 8-bit Integer Type Format
dof-2010-2-pdu-2Instance of Type Identifier
|
3.1.2. Unsigned 16-bit Integer
The value is two bytes using Integer Wire Format.
|
Unsigned 16-bit Integer Type Format
dof-2010-2-pdu-3Instance of Type Identifier
|
3.1.3. Unsigned 32-bit Integer
The value is four bytes using Integer Wire Format.
|
Unsigned 32-bit Integer Type Format
dof-2010-2-pdu-4Instance of Type Identifier
|
3.1.4. Unsigned 64-bit Integer
The value is eight bytes using Integer Wire Format.
|
Unsigned 64-bit Integer Type Format
dof-2010-2-pdu-5Instance of Type Identifier
|
3.1.5. Signed 8-bit Integer
The value is one byte using Integer Wire Format.
|
Signed 8-bit Integer Type Format
dof-2010-2-pdu-6Instance of Type Identifier
|
3.1.6. Signed 16-bit Integer
The value is two bytes using Integer Wire Format.
|
Signed 16-bit Integer Type Format
dof-2010-2-pdu-7Instance of Type Identifier
|
3.1.7. Signed 32-bit Integer
The value is four bytes using Integer Wire Format.
|
Signed 32-bit Integer Type Format
dof-2010-2-pdu-8Instance of Type Identifier
|
3.1.8. Signed 64-bit Integer
The value is eight bytes using Integer Wire Format.
|
Signed 64-bit Integer Type Format
dof-2010-2-pdu-9Instance of Type Identifier
|
3.2. Floating-point Types
There are two types of floating-point numbers supported: 32-bit and 64-bit.
The rules for different sizes of floating point types are all very similar. This document combines them with only a mention of the differences.
The main difference is the value format on the wire. In each case, the value on the wire contains the same number of bits as the type declares. The values use IEEE 754 formatting.
|
3.2.1. 32-bit Floating Point
The value is four bytes using Floating Point Wire Format.
|
32-bit Floating Point Type Format
dof-2010-2-pdu-11Instance of Type Identifier
|
3.2.2. 64-bit Floating Point
The value is eight bytes using Floating Point Wire Format.
|
64-bit Floating Point Type Format
dof-2010-2-pdu-12Instance of Type Identifier
|
3.3. String Type
DOF includes support for strings with defined encodings. Strings are variable-length, with a maximum byte length of 222 bytes (not characters). This length information is included in the data. The type definition defines the maximum number of characters, while on the wire it is the number of bytes.
|
Except for very special encodings, there is only a weak relationship between the maximum character length in the specification and the maximum byte length on the wire. For example, UTF-8 can take between 1 and 6 bytes per character. A UTF-8 string with a maximum character length of 10 could take up to 60 bytes on the wire. |
String types specify the encoding used in their definitions. In all cases, the encoding values uses the IANA assigned MIBenum values found at http://www.iana.org/assignments/character-sets. Use the preferred MIME name in all cases. Values less than three and greater than or equal to 3000 are reserved.
Localization and globalization of DOF applications is beyond the scope of this document. However, the design comes from the guidelines of RFC2277 and RFC2130. These RFCs provide guidelines for protocol design and best practices for the Internet community. The string type provided in DOF follow these guidelines by allowing multiple encodings.
|
String Wire Format
dof-2010-2-pdu-13
|
3.3.1. General Encoded String
|
General Encoded String Type Format
dof-2010-2-pdu-14Instance of Type Identifier
|
3.4. Date/Time Type
There is a single type for passing date and time information. The format uses milliseconds since Midnight, January 1, 1970 UTC. This is the same format used in the Java VM.
|
Date/Time Type Format
dof-2010-2-pdu-15Instance of Type Identifier
|
The value is passed as eight bytes using Integer Wire Format. The contents are milliseconds since Midnight, January 1, 1970 UTC.
3.5. Boolean Type
Boolean values are defined similar to the C Programming Language: a value of zero (0) is False, and any other value is interchangeably defined as True. The actual value passed may be modified on the wire and only the True and False values are guaranteed.
|
Boolean Type Format
dof-2010-2-pdu-16Instance of Type Identifier
|
The value is passed as one byte using Integer Wire Format. The value of zero is defined as False, any other value as True.
3.6. DOF IID Type
Interface Identifiers can be passed as values.
|
IID Type Format
dof-2010-2-pdu-17Instance of Type Identifier
|
The value is passed using Interface Identifier (IID).
3.7. DOF OID Type
Object Identifiers can be passed as values.
|
OID Type Format
dof-2010-2-pdu-18Instance of Type Identifier
|
The value is passed using Object Identifier (OID).
3.8. UUID Type
UUIDs, or Universally Unique Identifiers can be used as values.
|
UUID Type Format
dof-2010-2-pdu-19Instance of Type Identifier
|
The value is MSB first. See RFC 4122 for more information. Note that the rule for MSB first includes all fields. This is not the same as the typical UUID storage format (which is dependent on machine endianness).
3.9. BLOB Type
BLOB stands for Binary Large Object. DOF supports BLOBs for situations where a single entity (like an image) needs to be transmitted. Of course these can also be modeled as arrays of unsigned bytes, but that may confuse the semantics of the object.
|
BLOB Wire Format
dof-2010-2-pdu-20
|
3.9.1. BLOB Type Formatting
|
BLOB Type Format
dof-2010-2-pdu-21Instance of Type Identifier
|
3.10. Array Types
Both variable- and fixed-length arrays are supported in DOF. Arrays are simply lists where each element type is identical, and where the minimum and maximum lengths of the list can be specified as part of the type.
Variable-length arrays include both a maximum and a minimum length. This can be useful when at least a certain number of elements are required, although the minimum length can be zero.
Arrays include a single nested type specifier. This means that all array elements have the same type.
The full set of type definitions, including structures and arrays, are allowed as the nested types. This means that arrays of arrays, etc. are all allowed.
|
Array Wire Format
dof-2010-2-pdu-22
|
3.10.1. Array Type Formatting
|
Array Type Format
dof-2010-2-pdu-23Instance of Type Identifier
|
3.11. Reference Type
A reference type refers to a type in the type context by reference. It is important to note that the reference can be to any type in the context, either before or after the reference itself. However, it is impossible for a reference to refer to itself directly.
|
Reference Type Format
dof-2010-2-pdu-24Instance of Type Identifier
|
3.12. Nullable Type
The nullable type allows for the use of a null value on the wire in addition to the base type of the nullable type. This is similar to the handling of objects in the Java and C# languages, which allow for values to include a NULL. In the DOF type system there is no use of the NULL except as allowed by this type – in other words a type must be declared to allow the use of NULL.
The nullable type has a single sub-type, which is the type that it must take if the value NULL is not used.
|
Nullable Wire Format
dof-2010-2-pdu-25
|
|
Nullable Type Format
dof-2010-2-pdu-26Instance of Type Identifier
|
3.13. Structure Type
Structures are similar to fixed-length arrays, with the difference being that the elements can be of different types. In the same way, they are passed on the wire as a list of the corresponding component values.
|
Integer Wire Format
dof-2010-2-pdu-27
|
|
Nullable Type Format
dof-2010-2-pdu-28Instance of Type Identifier
|
4. External PDU Reference
4.1. DOF Common Types, OpenDOF TSC, [dof-2009-1] (7.0.1, 12 January 2018)
|
Compressed Unsigned 16-Bit
dof-2009-1-pdu-1 |
|
Compressed Unsigned 24-Bit
dof-2009-1-pdu-2
|
|
Compressed Unsigned 32-Bit
dof-2009-1-pdu-3
|
|
Object Identifier (OID)
dof-2009-1-pdu-4
|
|
Object Identifier Attribute
dof-2009-1-pdu-5
|
|
Interface Identifier (IID)
dof-2009-1-pdu-21 |
|
Type Identifier
dof-2009-1-pdu-23
|
|
Type Reference
dof-2009-1-pdu-40Instance of Compressed Unsigned 16-Bit
|